• +86 18258800889
  • jacky@hnbocon.com
  • 22nd Street,Hangzhou,China
19 years ethylene oxide sterilizer manufacturer

Precautions for ethylene oxide sterilization


 

type of ethylene oxide sterilization

Inner container volume OUTSIDE SIZE TRANSPORT SIZE INSEDE SIZE NET VOLUME
(L×W×H) (L×W×H) (L×W×H) (L×W×H)
1m3 1700×2050×1790 1505×1790×1790 1260×800×1050 1.06m³
3m3 1850×2950×2875 1850×1550×2400 1400×1350×1700 3.21m³
6m3 3250×2950×2875 3250×1550×2400 2800×1350×1700 6.43 m³
10m3 4950×2950×2875 4950×1900×2400 4500×1350×1700 10.33 m³
15m3 7200×2950×2875 7200×1900×2400 6750×1350×1700 15.491m³
20m3 9450×2950×2875 9450×1900×2400 9000×1350×1700 20.66 m³
25m3 10500×3150×2875 10500×2000×2400 10000×1500×1700 25.50 m³

Precautions for ethylene oxide sterilization
1、 Operate in strict accordance with the confirmed sterilization process and keep complete records to ensure the sterilization effect of the product. 
2、 Strictly distinguish sterilized products from non sterilized products, and do not mix them up. 
3、 No fireworks are allowed in the operation area. The electrical switch must be explosion-proof, and the lamp must be explosion-proof. 
4、 In case of leakage of ethylene oxide, measures must be taken immediately to spray water. In case of poisoning, it must be sent away from the site immediately. In case of serious poisoning, it shall be sent to the hospital immediately for rescue. If the EO enters the eye or the skin, it should be

washed with water immediately. 
5、 During the operation, pay close attention to the temperature and pressure changes of the box, and adjust according to the changes. 
6、 Special personnel must be assigned to pay close attention to the change of pressure in the process of vacuum pumping, dosing, air exchange and other operations that have a great impact on pressure. In case of any abnormality, report to relevant departments immediately.
7、 When loading and unloading products, handle them with care. Rough loading and unloading (especially syringe products) is strictly prohibited. 
8、 Clean and maintain the sterilization cabinet regularly to reduce the pollution of the cabinet to the product packaging.
9、 Maintain the sterilization cabinet regularly, check it at any time, and discover all kinds of potential safety hazards in time.
10、 In case of equipment failure, it shall be reported to the equipment department for maintenance and repair, and operation with defects is strictly prohibited. 
11、 It is strictly prohibited for miscellaneous personnel to enter the sterilization room.

Comments:

Get in touch

ask