EO Sterilizer with humidity above 90%

Special configuration of sterilizer with humidity above 90%. The following is the answer for requirement of 90% humidity in the sterilizing process after calculation: 1. The humidity sensor must be visala brand. Other humidity sensors cannot accurate...

Read More

Which of the following factors influence ethylene oxide ster

Five factors affecting the sterilization of ethylene oxide: temperature, pressure, humidity, ethylene oxide concentration and sterilization time 1、 Temperature The conventional limit of temperature is usually 37 ℃ ~ 63 ℃, and the suit...

Read More

Which of the following factors influence ETO sterilization

The factors that affect the sterilization effect are temperature, humidity, concentration, time, pressure, packaging method, etc. 1. Temperature: The conventional limit of temperature is generally 44 ℃ ~ 56 ℃, and the most commonly used temperatu...

Read More

Methods to reduce EO residue

The method of reducing EO residue should be established to make the sterilized products meet the requirements of iso10993-7. It is necessary to control EO residue in medical devices after EO processing by proper ventilation. It is important to consid...

Read More

Application scope of ethylene oxide sterilization

Application scope of ethylene oxide sterilization Ethylene oxide does not damage the sterilized articles and has strong penetration, so most articles that are not suitable for general sterilization can be sterilized and sterilized with ethy...

Read More

The characteristics of the eo sterilizer

The characteristics of the eo sterilizer 1.operation process by PLC+ industrial computer automatic control, built-in high precision sensor and anti-interference system, circuit detection of temperature, relative humidity, pressure, and set the value...

Read More

6 cubic meters medical EO sterilizer

6 cubic meters medical EO sterilizer Advanced Modele Standard Components cabinet volume 6m cabinet size inside:Length x Width x Height =2600*1350*1700 overall size outer:Length x Width x Height =3200*2100*2300 Chamber pressure range design pressu...

Read More

Is sterility test required for mask

Q:Is sterility test required for mask? A:Not necessarily. According to the international practice, that is to say, the European Union or the United States generally do not need to carry out sterility test of products. As long as the sterilization is...

Read More

Introduction of EO sterilizer equipment sterilization proces

The laboratory is equipped with a 100 level clean operation platform, a 10000 level sterile test and purification room, a bi incubator, and a gas chromatograph for EO / ECH analysis and test. Biological indicator (BI) test; product sterility test; et...

Read More

Maintenance of sterilizer

Maintenance of sterilizer equipment Preventive maintenance shall be planned and implemented in accordance with documented procedures. Procedures shall be documented and maintenance personnel shall be trained. Only after all specified maintenance tasks...

Read More